Generator in winter: how to start it in the cold and which fuel and oil to use

Marsun MHD20H 20 kW trifazis dyzelinis generatorius su įmontuotu ATS ir šildomu kuro bloku

To make sure your generator starts in freezing weather, check the fuel, the oil and the starter battery before winter. In the cold, engine friction increases, the battery gets weaker, and a diesel engine needs winter diesel. In the Hybrid Energy catalogue, seven Marsun models have a heated fuel block that makes starting at low temperatures easier: MHD20H, MHD25H, MHD40, MHD50, MHD80, MHD100 and MHD250.

Key points

  • According to fueleconomy.gov, which is maintained by the US Department of Energy and the Environmental Protection Agency, cold oil increases engine friction in cold weather, and the battery gets weaker.
  • ORLEN Lietuva produces summer, transitional, winter and arctic (classes 0, 1 and 2) diesel; for the cold season, kerosene is added to diesel to improve the fuel’s filterability in the cold.
  • Choose oil according to your model’s manual: according to Marsun, SAE 10W-30 is recommended for the petrol models, while the product pages for the diesel MVD6, MVD8, MVD10, MVD12, MVD15 and MHD20H–MHD250 list 15W-40.
  • How to store fuel and what oil viscosity to use is stated in your model’s manual.
  • Only some liquid-cooled MHD models have a heated fuel block; the home models MVD6, MVD8, MVD12 and MVD15 do not, so the right fuel and a charged battery matter especially for them.

Why a generator is harder to start in the cold

Cold affects the oil, the battery and the fuel at the same time. The fueleconomy.gov website, maintained by the US Department of Energy and the Environmental Protection Agency, says that in cold weather, cold oil and other fluids increase engine friction and the battery performs less well. That page is about cars, but it is likely that a generator’s starter also needs more energy in the cold, while a cold battery delivers less.

For a diesel engine, the fuel matters too. ORLEN Lietuva says that kerosene is added to diesel for the cold season because kerosene has a better cold filter plugging point than diesel. This temperature (CFPP) shows how well fuel passes through a filter in the cold. If the fuel thickens and can no longer pass through the filter, the engine may not start.

A heated fuel block is there to make cold starts easier. The Marsun MHD20H description states that it makes starting the engine at low temperatures easier and that this model is worth choosing if the generator will have to start in the cold. The product pages do not say what exactly the block heats or at what temperature it switches on.

Which fuel to use in winter: diesel and petrol

In winter, fill a diesel generator with winter diesel. ORLEN Lietuva says it produces summer, transitional and winter diesel, as well as arctic diesel of classes 0, 1 and 2. The diesel page on the ORLEN website does not say which temperature each grade is for, so ask at the filling station which grade is on sale at the time.

If fuel has been left in the generator’s tank since summer, use it up in test runs before the frosts and then fill up with winter diesel. The tanks of the home models are small: the Marsun MVD6, MVD8 and MVD10 hold 12.5 l each, and the MVD12 and MVD15 hold 25 l each, so changing the fuel is easy. Decide in advance where you will keep your fuel supply: the MVD12 description mentions fuel storage together with the generator’s location and ventilation.

How to store petrol and what oil viscosity to use in a petrol generator is stated in your model’s manual. If you do not have the Marsun manual, contact Hybrid Energy.

Which oil to use in a generator in winter

Choose oil according to your generator manufacturer’s recommendation. Based on Marsun data, the Hybrid Energy product pages list SAE 10W-30 for the petrol models, while the pages for the diesel MVD6, MVD8, MVD10, MVD12, MVD15 and MHD20H–MHD250 list 15W-40. Check the viscosity and the fuel storage conditions in your model’s manual.

Model Fuel, power Starting Recommended oil (manufacturer’s data) Oil capacity
Marsun MVB6PI petrol, 5.5 kW, single-phase electric (push button) SAE 10W-30 0.6 l
Marsun MVB6 petrol, 5.5 kW, three-phase electric (key) SAE 10W-30 1.1 l
Marsun MVB8 petrol, 7.5 kW, three-phase electric SAE 10W-30 1.1 l
Marsun MVD6 diesel, 5.5 kW, three-phase electric 15W-40 1.65 l
Marsun MVD8 diesel, 7.5 kW, three-phase electric 15W-40 1.65 l
Marsun MVD10 diesel, 9 kW, three-phase electric 15W-40 1.65 l
Marsun MVD12 diesel, 11 kW, three-phase electric (key) 15W-40 2.8 l
Marsun MVD15 diesel, 14 kW, three-phase electric (key) 15W-40 3.5 l
Marsun MHD20H diesel, 20 kW, three-phase electric starter 15W-40 9.5 l

Data from the Hybrid Energy product pages (Marsun manufacturer’s data, catalogue as of 26 November 2026). The MVD8, MVD12 and MVD15 are delivered without engine oil, so before the first start you need to add 1.65 l, 2.8 l and 3.5 l of 15W-40 oil respectively.

The Hybrid Energy catalogue also includes engine oil for diesel generators 10W-30, API CI-4 (1 l): 9 €. The product description says that oil change intervals are set by the generator manufacturer, so check its requirements before buying. The product pages for the diesel Marsun MVD6, MVD8, MVD10, MVD12, MVD15 and MHD20H–MHD250 list 15W-40, so before using 10W-30, ask Hybrid Energy whether it is suitable for your generator.

Starter battery in the cold

A generator with electric start is turned over by a starter powered by a battery, and the battery gets weaker in the cold. In the Hybrid Energy catalogue, electric start is available on all diesel Marsun MVD and MHD models, on the petrol MVB6, MVB7, MVB8, MVB10, MVB6PI and MVBG6PI, and on all kits with ATS. The Marsun MVB2PI, MVB3.5PI and MVBG3.5PI are started by hand, so they do not depend on a battery.

The Marsun product pages state neither the battery capacity and voltage nor whether a generator on standby keeps its own battery charged. So before winter, check that the terminals are clean and tight and that the generator starts on the first try. If the starter turns sluggishly, charge the battery or ask a specialist to check it.

This is especially important if the generator is started by an ATS or by a hybrid inverter through a Two-Wire connection. An ATS is an automatic transfer switch: when grid voltage is lost, it starts the generator itself and switches the house over to generator power. The automation only sends a start signal, and the engine has to start on its own, so automation will not help if the battery is weak or the fuel is not suited to the cold. We explained how an ATS and automatic start work in the article generator transfer switch: manual or ATS.

Generators with a heated fuel block

If the generator stands outdoors and has to start automatically in freezing weather, choose a model with a heated fuel block. According to the manufacturer’s data, seven Marsun MHD models in the Hybrid Energy catalogue have such a block; all of them are liquid-cooled and have a built-in ATS, so no separate transfer switch is needed.

Model Rated / max. power ATS Fuel tank Oil (manufacturer’s data) Price
Marsun MHD20H 20 kW / 22 kW built-in 70 l 15W-40, 9.5 l 9 099 €
Marsun MHD25H 25 kW / 27 kW built-in 70 l 15W-40, 9.5 l 9 799 €
Marsun MHD40 40 kW / 44 kW built-in 70 l 15W-40, 9.5 l 11 999 €
Marsun MHD50 50 kW / 55 kW built-in 120 l 15W-40, 13 l 12 899 €
Marsun MHD80 80 kW / 88 kW built-in 120 l 15W-40, 17 l 16 699 €
Marsun MHD100 100 kW / 110 kW built-in 160 l 15W-40, 17 l 18 299 €
Marsun MHD250 250 kW / 280 kW built-in 1000 l 15W-40, 28 l 34 799 €

Prices are shown as in the catalogue; technical data come from the product pages (catalogue as of 26 November 2026, MHD20H page checked on 27 November 2026). All models are three-phase diesel units with electric start.

The smallest of these generators is rated at 20 kW, so they suit a larger house, a farm or a business. The home models MVD6, MVD8, MVD12 and MVD15 have no heated fuel block, so in the cold season winter fuel, the right oil and a charged battery are especially important for them. We explained how to work out what generator power your home needs in the article home generator: power, ATS and three-phase connection, and you will find generators with installation on the page home generators with installation.

Test run before winter

It is best to check the generator now, while you still have power. As we wrote in the article how to prepare for a power cut, a generator that has not been started for a long time may fail to start on the day you need it. How often to do a test run is stated in your model’s manual; if you do not have it, ask Hybrid Energy.

For the test, start the generator outdoors, in the place where it will run during a power cut, not in the garage. We explained why it must not be run in a garage and how far from windows to place it in the article quiet generator for home and where to put it. If you have an ATS, check together with an electrician how it switches the house over when the grid is disconnected: when Hybrid Energy installs the generator, this check is included in the price.

What you can do yourself

Checklist before winter:

  1. Start the generator outdoors now, while you still have power, and make sure it starts on the first try.
  2. Check the oil level and grade against the manual (SAE 10W-30 for the Marsun petrol models; 15W-40 on the product pages for the diesel MVD6, MVD8, MVD10, MVD12, MVD15 and MHD20H–MHD250). A new MVD8, MVD12 or MVD15 is delivered without oil.
  3. In a diesel generator, use up the fuel left over from summer and fill up with winter diesel.
  4. For a petrol generator, check the fuel storage and oil viscosity requirements in the model’s manual.
  5. Check the starter battery: the terminals, the charge and whether the starter turns briskly.
  6. Get a supply of winter fuel and decide in advance where you will keep it.
  7. Take photos of the generator’s rating plate and your distribution board and, if you need installation or advice, send them through the enquiry form.

What we will do

Hybrid Energy generator installation and start-up cost from €400. This covers choosing the backup power layout, connecting the generator, starting it up and testing it with the grid disconnected. The work is done by a certified electrician. We work anywhere in Lithuania, and installation usually takes no more than one working day.

If the generator has to start automatically in the cold, we will help you choose a model with a built-in ATS and a heated fuel block, or a layout with a separate ATS. Before any work you receive a quote that lists equipment, labour, materials, delivery and the final total separately; the offer is valid for 10 working days. Delivery within Lithuania is free, and the generator comes with a 2-year statutory warranty. We will also help you check whether an oil is suitable for your generator.

Email sales@hybridenergy.lt, call +370 636 52 222 (Mon–Fri 9:00–18:00) or fill in the form.

Frequently asked questions

Why won’t a generator start in the cold?

Three things can make a generator harder to start in the cold: cold oil increases engine friction, the battery gets weaker, and a diesel engine needs fuel suited to low temperatures. These causes are given by fueleconomy.gov (friction, battery) and ORLEN Lietuva (fuel filterability). Hybrid Energy recommends doing a test start outdoors before winter, checking the oil against the manual, charging the battery and filling up with winter fuel.

What oil should I use in a generator in winter?

The oil your model’s manufacturer specifies. Based on Marsun data, the Hybrid Energy product pages recommend SAE 10W-30 for the petrol models, while the pages for the diesel MVD6, MVD8, MVD10, MVD12, MVD15 and MHD20H–MHD250 list 15W-40. Check the oil viscosity and fuel storage requirements in your model’s manual, and Hybrid Energy will help you check whether an oil is suitable for your generator.

Can I leave summer diesel in the tank over winter?

It is better not to: summer diesel is made for the warm season, so in winter use winter diesel. ORLEN Lietuva produces summer, transitional, winter and arctic diesel as separate grades, and for the cold season it adds kerosene to the fuel, which improves the filterability of diesel in the cold. Hybrid Energy recommends using up summer fuel in test runs and filling the tank with winter diesel before the frosts.

Which generators have a heated fuel block?

According to the manufacturer’s data, in the Hybrid Energy catalogue the Marsun MHD20H, MHD25H, MHD40, MHD50, MHD80, MHD100 and MHD250 have a heated fuel block. All of them are diesel, three-phase, liquid-cooled and have a built-in ATS. The MHD20H description states that the block makes starting the engine at low temperatures easier. The MVD6, MVD8, MVD12 and MVD15 do not have it.

How long can petrol stay in a generator’s tank?

The exact storage time is given in your model’s manual; follow the manual when choosing the oil viscosity as well. If you do not have the manual for your Marsun petrol model, ask Hybrid Energy before storing the generator for a longer period. The petrol MVB6, MVB7, MVB8 and MVB10 have electric start, so check the starter battery before winter too.

Sources

  • U.S. Department of Energy and EPA, Fuel Economy in Cold Weather: fueleconomy.gov/feg/coldweather.shtml: in cold weather, cold oil increases friction and battery performance drops (checked 27 November 2026).
  • ORLEN Lietuva, Diesel Fuel: orlenlietuva.lt: summer, transitional, winter and arctic (classes 0, 1, 2) diesel; kerosene is added for the cold season because of its better cold filter plugging point (checked 27 November 2026).
  • Marsun manufacturer’s data in the Hybrid Energy product pages: MHD20H, MVD8, MVD12, MVD15 (checked 27 November 2026); the other models are based on catalogue data from 26 November 2026.
  • Hybrid Energy, engine oil for diesel generators 10W-30, API CI-4: hybridenergy.lt (checked 27 November 2026).
  • Hybrid Energy, generator transfer switch: manual or ATS: hybridenergy.lt; how to prepare for a power cut: hybridenergy.lt (checked 27 November 2026).