Marsun MVD6 5.5 kW Three-Phase Diesel Generator with AVR and Two-Wire Start
€1,669.00
Marsun MVD6 is a 5.5 kW (6 kW max) three-phase diesel generator in a soundproof canopy (72 dB), with a 12.5 l tank and a Two-Wire Switch connection for automatic start.
- Free delivery across Lithuania
- 14-day returns — we pay for the return shipping
- Manufacturer warranty, CE compliant
The Marsun MVD6 is a three-phase diesel generator rated at 5.5 kW continuous and 6 kW maximum, at 230/400 V with equal power on each phase (Equal Power). It is the smaller of the two neighbouring models: the recommended long-term load is 4.1–4.4 kW (MVD8: 5.6–6.0 kW), so the MVD6 suits lighter loads where longer running matters: the 12.5 l tank lasts about 7 hours at full load (MVD8: about 5 hours, an approximate calculation). It is also lighter, at 170 kg. It has an air-cooled 188FE engine, a soundproof canopy, AVR, electric start and a factory Two-Wire Switch connection that lets a hybrid inverter or an ATS cabinet start it automatically. The manufacturer states up to 12 hours of continuous running.
Technical specifications
| Parameter | Value |
|---|---|
| Fuel type | diesel |
| Cooling | air |
| Rated power | 5.5 kW |
| Maximum power | 6 kW |
| Rated AC voltage | 230 V / 400 V |
| Frequency | 50 Hz |
| Phases | three-phase |
| Equal power on each phase | yes |
| Engine model | 188FE |
| Engine type | single-cylinder, 4-stroke, air-cooled |
| Displacement | 456 cm³ |
| Engine speed | 3600 rpm |
| Recommended engine oil | 15W-40 |
| Oil quantity | 1.65 l |
| Noise level | 72 dB |
| Continuous running time | 12 h |
| Fuel consumption | 274 g/kWh |
| Fuel tank capacity | 12.5 l |
| Weight | 170 kg |
| Dimensions (L × W × H) | 920 × 540 × 760 mm |
| Soundproof canopy | yes |
| Start | electric |
| Voltage regulation | AVR |
| Frequency and voltage indicator | yes |
| Automatic start connection | Two-Wire Switch |
| ATS module | optional, bought separately |
| Heated fuel block | no |
| Shut-off when 10% of fuel is left | no |
| Online monitoring / Modbus | no |
| Protections | against running without load, against overload (circuit breaker) |
Download the manufacturer datasheet (PDF)
How the MVD6 differs from the MVD8
| Parameter | MVD6 | MVD8 |
|---|---|---|
| Rated / maximum power | 5.5 / 6 kW | 7.5 / 8 kW |
| Recommended long-term load (75–80%) | 4.1–4.4 kW | 5.6–6.0 kW |
| Engine | 188FE, 456 cm³ | 192FE, 499 cm³ |
| Fuel use at full load (calculated) | about 1.8 l/h | about 2.5 l/h |
| Run time on the 12.5 l tank at full load (calculated) | about 7 h | about 5 h |
| Weight and dimensions | 170 kg, 920 × 540 × 760 mm | 180 kg, 980 × 550 × 760 mm |
Both models share the same 12.5 l fuel tank, 72 dB noise level, 230/400 V output, 15W-40 oil (1.65 l), soundproof canopy and Two-Wire Switch connection.
Choose the MVD6 if your load is light (around 4.1–4.4 kW) and you want a longer run on one tank: about 7 hours at full load. If you need more power (recommended long-term load 5.6–6.0 kW), take the Marsun MVD8.
Diesel generator for a home: what is the MVD6 used for?
By design the MVD6 suits backup power for homes and farms, solar systems with storage (when there is little sun and the battery is empty), building sites, workshops, allotments and outdoor events. Of the two neighbouring models the MVD6 is the smaller one: 5.5 kW rated, with a recommended long-term load of 4.1–4.4 kW.
How much fuel does the MVD6 use and how long does a full tank last?
The manufacturer states that the MVD6 is designed for up to 12 hours of continuous running, with a 12.5 l fuel tank. It does not say what load that time applies to.
An approximate calculation at full load: 274 g/kWh × 5.5 kW ÷ 1000 = about 1.51 kg of diesel per hour. Dividing by a diesel density of 0.84 kg/l gives about 1.8 l/h, so the 12.5 l tank lasts roughly 7 hours at full rated power. This is an estimate based on the manufacturer’s consumption figure, not a measurement.
How does the MVD6 start automatically from a hybrid inverter?
The MVD6 has a factory Two-Wire Switch connection. It is a simple two-wire connection with a potential-free (dry) contact: through it a hybrid inverter or an ATS cabinet starts and stops the generator on its own, with nothing for you to do.
- A hybrid or off-grid inverter decides by itself when it needs extra energy. The generator connects to the inverter’s generator input.
- With an inverter, a separate ATS cabinet is not needed.
- At a site without solar panels, an ATS cabinet monitors the grid and starts the generator when the voltage drops out.
When the circuit closes the generator starts, and when it opens the engine shuts down safely. The manufacturer’s compatibility list includes Deye, Solis, Solplanet, GoodWe, Victron Energy and Sungrow hybrid inverters. Connection to the building’s wiring and ATS configuration must be done by a qualified electrician.
How do you connect a backup generator to a house?
A generator is connected to the building’s internal wiring through a fixed connection, and the changeover can be automated with a hybrid inverter or a separately bought ATS module. ESO (Lithuanian grid operator) states, in its recommendations for installing a backup source:
“A generator may be connected to the internal electrical network of a whole building only by installing a fixed connection and measures that ensure the voltage produced by the generator is not fed into ESO’s networks… Entrust this work only to qualified specialists.”
ESO also advises choosing the power according to your existing connection capacity, and when connecting single-phase loads to a three-phase generator, taking the single-phase limit into account, because the datasheet gives the combined power of all three phases.
We handle it for you. We select the equipment for your site, deliver anywhere in Lithuania, install and connect it.
Load and phases: 400 V and 230 V from one generator
From a typical three-phase generator, a single-phase socket can draw only one third of the total power. The MVD6 has an Equal Power system, with equal power on each phase, so its capacity can be used both through the 400 V power socket and through the 230 V single-phase socket.
A generator should not run at full (100%) load for long. The recommended operating range for the engine and alternator is 75 to 80% of rated power, which for the MVD6 is about 4.1 to 4.4 kW. In a system with a battery, add the power the generator will use to charge the batteries to the building’s demand.
What to know before buying
- Noise and canopy. The generator is supplied in a soundproof canopy, with a manufacturer-stated noise level of 72 dB. Choose the location with neighbours and ventilation in mind.
- Weight and size. 170 kg, 920 × 540 × 760 mm.
- Automatic changeover. There is no built-in ATS. A hybrid inverter starts the generator automatically through the Two-Wire Switch connection; at a site without an inverter you need a separately bought ATS module.
- Fuel and oil. The generator runs on diesel. It is supplied without engine oil: before the first start, add 1.65 l of 15W-40.
- What the model does not have. The MVD6 has no heated fuel block, no automatic shut-off at 10% fuel, and no online or Modbus monitoring.
Frequently asked questions
How long does the Marsun MVD6 run on a full tank?
At a full 5.5 kW load the 12.5 l tank lasts roughly 7 hours (an approximate calculation based on 274 g/kWh). The manufacturer states up to 12 hours of continuous running but does not specify the load.
How much fuel does the 5.5 kW MVD6 diesel generator use?
The manufacturer states 274 g/kWh, which at a 5.5 kW load is about 1.51 kg, or roughly 1.8 l of diesel, per hour. This is an approximate calculation.
Is the MVD6 a diesel generator with ATS?
The MVD6 has no built-in ATS; the ATS module is bought separately. With a hybrid inverter you do not need one, because the inverter starts the generator through the Two-Wire Switch connection.
Which inverters is the MVD6 compatible with?
The manufacturer’s compatibility list includes Deye, Solis, Solplanet, GoodWe, Victron Energy and Sungrow hybrid inverters. Hybrid Energy checks the connection diagram for your specific inverter and connects the system.
Can the MVD6 be connected straight to the house’s distribution board?
No, only through a fixed connection with measures that keep voltage from reaching the ESO grid, and only by qualified specialists. That is what the ESO recommendations for installing a backup source say.
Is the MVD6 diesel generator suitable for a house, a farm or a building site?
Yes. The MVD6 is meant for backup power for homes and farms, solar systems with storage, building sites, workshops, allotments and outdoor events. The recommended long-term load is about 4.1 to 4.4 kW.
How loud is the MVD6?
The manufacturer states a noise level of 72 dB, and the generator is supplied in a soundproof canopy.
Can single-phase appliances be connected to the three-phase MVD6?
Yes. The MVD6 has an Equal Power system with equal power on each phase, so the 230 V socket can be used too. Keep in mind that pumps and compressors draw 2 to 5 times more current when they start.
Does Hybrid Energy install the generator?
Yes. Hybrid Energy delivers the MVD6 anywhere in Lithuania, installs it, connects it to your site or hybrid inverter and commissions it. A consultation before you buy is free.
How does the Marsun MVD6 differ from the MVD8?
The MVD6 is rated at 5.5 kW (MVD8: 7.5 kW) with a recommended long-term load of 4.1–4.4 kW (MVD8: 5.6–6.0 kW). At full load the 12.5 l tank lasts about 7 hours (MVD8: about 5 hours); the MVD6 weighs 170 kg, the MVD8 180 kg.
Sources
- Marsun MVD6 manufacturer datasheet (PDF), checked 2026-10-26
- ESO: Recommendations for installing a backup source (in Lithuanian), checked 2026-10-26
| Dimensions | 92 × 54 × 76 cm |
|---|---|
| Power | 5.5 kW |
| Phases | Three-phase |
| Brand | Marsun |

Reviews