Midea M-Thermal-14B3HB2 is a three-phase split air-to-water heat pump: 14.50 kW at A7W35, COP 4.70, SCOP 4.72.

  • Free delivery across Lithuania
  • 14-day returns — we pay for the return shipping
  • Manufacturer warranty, CE compliant
SKU: M-Thermal-14B3HB2 Categories: ,
Description

Midea M-Thermal-14B3HB2 is the middle three-phase (380–415 V) model between 12 and 16 kW: it delivers 14.50 kW of heat at A7W35 with COP 4.70, SCOP 4.72 (35 °C) and 3.47 (55 °C), and its outdoor unit has a sound power level of 65 dB(A). It has 2.40 kW more capacity than the M-Thermal-12B3HB2 and 1.50 kW less than the M-Thermal-16B3HB2, and its COP and SCOP (35 °C) also sit between the two. It fits when 12 kW is too little for the building’s heat loss and 16 kW is not needed.

Technical specifications

Parameter Value
Kit model M-Thermal-14B3HB2
Outdoor unit MHA-V14W/D2RN8-B2
Indoor unit (wall-mounted hydraulic module) HB-A160/CDS90GN8-B2
Power supply (outdoor and indoor unit) 380–415 V / 3 / 50 Hz
Phases three-phase
Built-in electric heater 9 kW / 3 stages
Heating capacity A7W35 (ΔT=5) 14.50 kW; power input 3.09 kW; COP 4.70
Heating capacity A7W45 (ΔT=5) 14.20 kW; power input 3.89 kW; COP 3.65
Heating capacity A7W55 (ΔT=5) 13.80 kW; power input 4.60 kW; COP 3.00
Cooling capacity A35W7 (ΔT=5) 12.70 kW; power input 4.98 kW; EER 2.55
Cooling capacity A35W18 (ΔT=5) 13.50 kW; power input 3.74 kW; EER 3.61
Seasonal efficiency class A+++ (35 °C) / A++ (55 °C), average climate
SCOP 4.72 (35 °C) / 3.47 (55 °C)
Seasonal space heating efficiency ηs 185.6 % (35 °C) / 135.6 % (55 °C)
Annual electricity consumption 6013 kWh (35 °C) / 7203 kWh (55 °C)
Refrigerant R32, 1.84 kg
CO2 equivalent 1242.0 kg
Outdoor temperature, heating −25 to 35 °C
Outdoor temperature, cooling −5 to 43 °C
Outdoor temperature, domestic hot water −25 to 43 °C
Water temperature, heating 25–65 °C
Water temperature, cooling 5–25 °C
Water temperature, domestic hot water 20–60 °C
Max. refrigerant pipe length 30 m
Pipe length without extra refrigerant 15 m
Max. height difference between units 20 m
Refrigerant connections gas 5/8″ / liquid 3/8″
Water connections (flow / return) 1″ / 1″
Water flow rate 0.70–3.00 m³/h
Sound power level (outdoor / indoor) 65 dB(A) / 43 dB(A)
Sound pressure level at 1 m (outdoor / indoor) 51 dB(A) / 32 dB(A)
Outdoor unit dimensions (W × H × D) 1118 × 865 × 523 mm
Indoor unit dimensions (W × H × D) 420 × 790 × 270 mm
Control wired controller and mobile app
Compressor and technology twin rotary, DC inverter
Communication Modbus RTU; cascade connection

Download the manufacturer datasheet (PDF)

How the M-Thermal-14B3HB2 differs from M-Thermal-12B3HB2 and M-Thermal-16B3HB2

Parameter M-Thermal-12B3HB2 M-Thermal-14B3HB2 M-Thermal-16B3HB2
Heating capacity A7W35 12.10 kW 14.50 kW 16.00 kW
COP at A7W35 4.95 4.70 4.50
SCOP (35 °C) 4.81 4.72 4.62
Annual electricity consumption (35 °C) 5153 kWh 6013 kWh 6805 kWh
Outdoor unit sound power level 64 dB(A) 65 dB(A) 68 dB(A)
Cooling capacity A35W7 11.60 kW 12.70 kW 14.00 kW

Choose the M-Thermal-14B3HB2 when the M-Thermal-12B3HB2 (12.10 kW) is too small for the building’s heat loss and the M-Thermal-16B3HB2 (16.00 kW) is more than you need. In return for 2.40 kW more capacity than the 12 kW model, the COP at A7W35 is lower (4.70 vs 4.95) and annual electricity consumption at 35 °C is higher. All three three-phase models share the same indoor module HB-A160/CDS90GN8-B2, 9 kW heater, 1.84 kg of R32 and dimensions; what differs is capacity, efficiency and outdoor unit noise.

What flow temperature does the M-Thermal-14B3HB2 heat pump supply?

In heating mode M-Thermal-14B3HB2 supplies water at 25–65 °C and works at outdoor temperatures from −25 to 35 °C. The higher the flow temperature, the lower the COP: 4.70 at A7W35, 3.65 at A7W45 and 3.00 at A7W55, with heating capacity of 14.50, 14.20 and 13.80 kW respectively.

  • Seasonal efficiency: SCOP 4.72 at 35 °C and 3.47 at 55 °C.
  • Seasonal space heating efficiency ηs: 185.6 % (35 °C) and 135.6 % (55 °C).
  • Annual electricity consumption per the manufacturer: 6013 kWh (35 °C) and 7203 kWh (55 °C).

We agree the flow temperature (underfloor heating or radiators) with you, because real-world efficiency depends on it.

Split air to water heat pump: outdoor unit, hydraulic module and connections

M-Thermal-14B3HB2 consists of the outdoor unit MHA-V14W/D2RN8-B2 and the wall-mounted hydraulic module HB-A160/CDS90GN8-B2, linked by refrigerant piping up to 30 m long. The module already contains a circulation pump, expansion vessel, sensors and protection devices, which means less work on site during installation.

  • Piping: up to 15 m without topping up refrigerant, height difference between the units up to 20 m; connections gas 5/8″, liquid 3/8″.
  • Water side: connections 1″ / 1″, flow rate 0.70–3.00 m³/h.
  • Control and communication: wired controller, mobile app, Modbus RTU, cascade connection.
  • Additional heat sources: these can be connected, according to the manufacturer’s datasheet.

Does the M-Thermal-14B3HB2 heat pump make domestic hot water?

M-Thermal-14B3HB2 heats domestic hot water to 20–60 °C and can do so at outdoor temperatures from −25 to 43 °C. The built-in 9 kW electric heater (3 stages) switches on automatically during peak load or in very cold conditions. The specification of this kit does not state a hot water tank capacity, so we select it to match your needs.

Why a heat pump must be installed by a certified specialist

M-Thermal-14B3HB2 uses R32 refrigerant (1.84 kg, CO2 equivalent 1242.0 kg), a fluorinated greenhouse gas. EU regulation requires people working with such equipment to be certified. The regulation states (our translation from the Lithuanian version):

“Natural persons carrying out the activities referred to in points (a), (b) and (c) of the first subparagraph of Article 10(1) shall be certified in accordance with Article 10.”

Regulation (EU) 2024/573 on fluorinated greenhouse gases

In practice this means you cannot connect a heat pump yourself: installation, refrigerant charging and servicing must be done by a certified specialist.

We handle it for you. We select the equipment for your site, deliver anywhere in Lithuania, install and connect it.

Frequently asked questions

How much heat does the M-Thermal-14B3HB2 deliver?

Midea M-Thermal-14B3HB2 delivers 14.50 kW of heat at A7W35 with COP 4.70, 14.20 kW at A7W45 (COP 3.65) and 13.80 kW at A7W55 (COP 3.00).

What electrical supply does the M-Thermal-14B3HB2 heat pump need?

Midea M-Thermal-14B3HB2 needs a three-phase 380–415 V / 3 / 50 Hz supply. Per the manufacturer’s datasheet, a three-phase connection is mandatory for this model.

What is the lowest outdoor temperature at which the M-Thermal-14B3HB2 still heats?

Midea M-Thermal-14B3HB2 heats at outdoor temperatures from −25 to 35 °C and supplies hot water from −25 to 43 °C.

What water temperature does the M-Thermal-14B3HB2 supply?

In heating mode Midea M-Thermal-14B3HB2 supplies water at 25–65 °C, for domestic hot water 20–60 °C and for cooling 5–25 °C.

What is the seasonal efficiency (SCOP) of the M-Thermal-14B3HB2?

Midea M-Thermal-14B3HB2 has a SCOP of 4.72 at 35 °C and 3.47 at 55 °C, efficiency class A+++ (35 °C) / A++ (55 °C) in average climate conditions.

Can the M-Thermal-14B3HB2 heat pump cool as well?

Yes, Midea M-Thermal-14B3HB2 cools: 12.70 kW at A35W7 (EER 2.55) and 13.50 kW at A35W18 (EER 3.61). Hybrid Energy helps you choose the right mode for your system.

How long can the refrigerant piping be with the M-Thermal-14B3HB2?

The maximum refrigerant pipe length between the units of the M-Thermal-14B3HB2 is 30 m, 15 m without topping up refrigerant, and the height difference can be up to 20 m.

How loud is the M-Thermal-14B3HB2?

The outdoor unit of Midea M-Thermal-14B3HB2 has a sound power level of 65 dB(A) and a sound pressure level of 51 dB(A) at 1 m; the indoor unit 43 and 32 dB(A).

Which refrigerant does the M-Thermal-14B3HB2 use and how much?

Midea M-Thermal-14B3HB2 uses R32 refrigerant, 1.84 kg (CO2 equivalent 1242.0 kg).

Can I install the M-Thermal-14B3HB2 heat pump myself?

No. Midea M-Thermal-14B3HB2 uses R32 gas, so only a certified specialist may install, charge and service it. Hybrid Energy does it for you: we deliver anywhere in Lithuania, install and connect it.

Sources