Midea M-Thermal PRO R32 All in One ALL-ONE-10A1/190B2 10 kW Heat Pump with 190 l Tank

€5,999.00

Midea ALL-ONE-10A1/190B2 is a 10 kW reversible air-to-water heat pump with a 190 l tank, COP 5.00 at A7W35 and heating down to −25 °C.

  • Free delivery across Lithuania
  • 14-day returns — we pay for the return shipping
  • Manufacturer warranty, CE compliant
SKU: ALL-ONE-10A1/190B2 Categories: ,
Description

The Midea M-Thermal PRO R32 All in One ALL-ONE-10A1/190B2 is the 10 kW model with the smaller, 190 l hot water tank: heating output at A7W35 is 10.00 kW (COP 5.00) and the indoor unit measures 600 × 1683 × 600 mm. It suits homes where most of the output goes to space heating and hot water use is moderate; if water is drawn at several points at once, the 240 l version is the better fit. The kit includes a 3 kW integrated electric heater, energy class A+++ (35 °C) / A++ (55 °C), 220–240 V, single phase.

Technical specifications

Parameter Value
Kit model ALL-ONE-10A1/190B2
Outdoor unit MHA-V10W/D2N8-B2
Indoor unit (hydromodule with tank) HBT-A100/190CDS90GN8-B2
Type reversible air-to-water heat pump, All in One (heating, cooling, hot water)
Power supply 220–240 V / 1 phase / 50 Hz
Heating output A7W35 / COP 10.00 kW / COP 5.00
Heating output A7W45 / COP 10.00 kW / COP 3.80
Heating output A7W55 / COP 9.50 kW / COP 3.10
Cooling output A35W7 / EER 8.20 kW / EER 3.31
Cooling output A35W18 / EER 10.00 kW / EER 4.80
Energy class (heating) A+++ (35 °C) / A++ (55 °C), average climate
SCOP 5.20 (35 °C) / 3.49 (55 °C)
Seasonal efficiency ηs 204.8 % (35 °C) / 136.6 % (55 °C)
Annual electricity consumption (per manufacturer data) 3,644 kWh (35 °C) / 4,539 kWh (55 °C)
Refrigerant R32, 1.65 kg (CO₂ equivalent 1113.8 kg)
Hot water tank 190 l, SUS 316L stainless steel (tank and heat exchanger), 45 mm insulation
Heat exchanger coil area / volume 1.86 m² / 9.53 l
Integrated electric heater 3 kW / 1 stage
Outdoor temperature, heating −25 °C to 35 °C
Outdoor temperature, hot water −25 °C to 43 °C
Outdoor temperature, cooling −5 °C to 43 °C
Supply water temperature, heating 25–65 °C
Supply water temperature, hot water 30–60 °C
Supply water temperature, cooling 5–25 °C
Water flow 0.7–3.0 m³/h
Maximum refrigerant pipe length 30 m
Length without extra refrigerant charge 15 m (beyond that, add 0.038 kg/m)
Maximum height difference between units 20 m
Refrigerant connections gas 5/8″, liquid 3/8″
Water connections heating 1″, hot water 3/4″
Sound power level, outdoor unit 60 dB(A)
Sound power level, indoor unit 42 dB(A)
Outdoor unit dimensions (W × H × D) 1118 × 865 × 523 mm
Indoor unit dimensions (W × H × D) 600 × 1683 × 600 mm
Indoor unit weight net / gross 140 / 161 kg
Indoor unit dimensions with packaging 730 × 1920 × 730 mm
Control mobile app; Modbus RTU; integrated heating / hot water valve
Other DC inverter technology, twin rotary compressor, condensate tray heater

Download the manufacturer datasheet (PDF)

How the ALL-ONE-10A1/190B2 differs from the ALL-ONE-10A1/240B2 and ALL-ONE-8A1/190B2

Parameter ALL-ONE-10A1/190B2 (this model) ALL-ONE-10A1/240B2 ALL-ONE-8A1/190B2
Heating output A7W35 / COP 10.00 kW / COP 5.00 10.00 kW / COP 5.00 8.30 kW / COP 5.20
Hot water tank 190 l 240 l 190 l
Indoor unit dimensions (W × H × D) 600 × 1683 × 600 mm 600 × 1943 × 600 mm 600 × 1683 × 600 mm
Indoor unit weight, net 140 kg 157 kg 140 kg
SCOP (35 °C / 55 °C) 5.20 / 3.49 5.20 / 3.49 5.22 / 3.36
Sound power level (outdoor / indoor unit) 60 / 42 dB(A) 60 / 42 dB(A) 59 / 40 dB(A)

Choose the ALL-ONE-10A1/190B2 if you need 10 kW and a compact indoor unit (1683 mm tall, 140 kg net) and hot water use is moderate. If hot water is drawn at several points at once, take the ALL-ONE-10A1/240B2: the same 10 kW outdoor unit, but a 240 l tank and a 1943 mm tall indoor unit. If the heat loss calculation is covered by 8.30 kW and quieter operation matters, look at the ALL-ONE-8A1/190B2 (59 / 40 dB(A) instead of 60 / 42 dB(A)).

What is an air to water heat pump with a built-in hot water tank, and who is the ALL-ONE-10A1/190B2 for?

The Midea ALL-ONE-10A1/190B2 is an “all in one” solution: the outdoor unit and the indoor hydromodule with a 190 l tank form one kit, and the compact indoor unit (600 × 1683 × 600 mm) suits places where space is tight. The 190 l tank suits moderate hot water use, where most of the output goes to heating the building.

  • Space heating: 10.00 kW at A7W35, 9.50 kW at A7W55
  • Summer cooling: 8.20 kW at A35W7
  • Hot water: 190 l tank, hot water temperature 30–60 °C

Is this air to water heat pump suitable for radiators? What the SCOP says

Seasonal efficiency (SCOP) is 5.20 at 35 °C supply water and 3.49 at 55 °C. The first figure applies to underfloor heating or low-temperature radiators, the second to higher-temperature systems. The manufacturer states annual electricity consumption of 3,644 kWh (35 °C) and 4,539 kWh (55 °C).

How do I choose the heat pump output and tank size?

Choose the output by the heat loss of the house, not by floor area alone. The outdoor unit MHA-V10W/D2N8-B2 is supplied with both the 190 l and the 240 l tank, so the tank can be chosen without changing the heating output; choosing a different output (10 or 8 kW) means a different outdoor unit, and the comparison is given above.

Heat pump installation: why you need a certified specialist

This heat pump uses R32 (1.65 kg), a fluorinated greenhouse gas. EU regulation requires people working with such equipment to be certified. The regulation states (translated from the Lithuanian text):

“Natural persons carrying out the activities referred to in points (a), (b) and (c) of the first subparagraph of Article 10(1) shall be certified in accordance with Article 10.”

Regulation (EU) 2024/573 on fluorinated greenhouse gases

The outdoor and indoor units can be separated by up to 30 m of refrigerant pipe and a height difference of up to 20 m; up to 15 m needs no additional refrigerant. Water connections: heating 1″, hot water 3/4″.

We handle it for you. We select the equipment for your site, deliver anywhere in Lithuania, install and connect it.

What to know before buying

  • Noise: sound power level 60 dB(A) for the outdoor unit and 42 dB(A) for the indoor unit.
  • Weight: the indoor unit weighs 140 kg (net); with packaging it measures 730 × 1920 × 730 mm.
  • Control: mobile app and Modbus RTU.
  • Operating limits: heating at −25 °C to 35 °C, cooling at −5 °C to 43 °C outdoors.
  • Water flow: 0.7–3.0 m³/h.

Frequently asked questions

What are the heating output and COP of the Midea ALL-ONE-10A1/190B2?

The Midea ALL-ONE-10A1/190B2 delivers 10.00 kW with COP 5.00 at A7W35. At A7W45 the output is 10.00 kW (COP 3.80), and at A7W55 it is 9.50 kW (COP 3.10).

Is a 190 l hot water tank enough?

A 190 l SUS 316L stainless steel tank with 45 mm insulation suits moderate hot water use, where most of the output goes to heating the building. If your needs are different, the same outdoor unit MHA-V10W/D2N8-B2 is also supplied with a 240 l tank. Hybrid Energy helps you choose the right option for your household.

Is this air to water heat pump suitable for radiators?

Yes, the supply water temperature for heating goes up to 65 °C (range 25–65 °C). SCOP is 5.20 at 35 °C and 3.49 at 55 °C, so efficiency is higher with low-temperature radiators or underfloor heating, and lower in older houses with high-temperature radiators.

Can the Midea ALL-ONE-10A1/190B2 also cool?

Yes, it is a reversible heat pump: cooling output is 8.20 kW at A35W7 (EER 3.31) and 10.00 kW at A35W18 (EER 4.80), at outdoor temperatures from −5 °C to 43 °C.

Down to what outdoor temperature do heating and hot water work?

Heating works at outdoor temperatures from −25 °C to 35 °C, and hot water preparation from −25 °C to 43 °C. Hot water temperature can be set between 30 and 60 °C.

How loud is the Midea ALL-ONE-10A1/190B2?

The sound power level is 60 dB(A) for the outdoor unit and 42 dB(A) for the indoor unit.

Can I install the heat pump myself?

No. The Midea ALL-ONE-10A1/190B2 uses R32 refrigerant (1.65 kg), so only certified specialists may work with it. Hybrid Energy delivers anywhere in Lithuania, installs and connects it.

What is the maximum refrigerant pipe length between the units?

The maximum refrigerant pipe length is 30 m and the height difference between the units up to 20 m. Up to 15 m needs no extra refrigerant; beyond that, 0.038 kg/m is added.

Does the Midea ALL-ONE-10A1/190B2 have an integrated electric heater?

Yes, the indoor unit has a 3 kW integrated electric heater (1 stage). It can be controlled through the mobile app, and Modbus RTU is also supported.

How much space do the indoor and outdoor units need?

The indoor unit measures 600 × 1683 × 600 mm (net weight 140 kg) and the outdoor unit 1118 × 865 × 523 mm. With packaging the indoor unit is 730 × 1920 × 730 mm.

Sources

Additional information
Dimensions60 × 168.3 × 60 cm
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Midea M-Thermal PRO R32 All in One ALL-ONE-10A1/190B2 10 kW Heat Pump with 190 l Tank”

Your email address will not be published. Required fields are marked *