Solis S6-EH3P80K10-NV-YD-H 80 kW three-phase hybrid inverter
€7,799.00
Solis S6-EH3P80K10-NV-YD-H is an 80 kW three-phase hybrid inverter with 10 MPPTs, two battery ports and an 80 kW backup output.
- Free delivery across Lithuania
- 14-day returns — we pay for the return shipping
- Manufacturer warranty, CE compliant
The Solis S6-EH3P80K10-NV-YD-H is an 80 kW three-phase (3/N/PE, 230/400 V) hybrid inverter with 10 MPPT trackers and two battery ports for high-voltage (300–950 V) batteries. The backup output is also 80 kW, and the switchover to backup takes less than 10 ms. It is designed for factories, warehouses, farms and shopping centres.
Technical specifications
| Parameter | Value |
|---|---|
| Model | S6-EH3P80K10-NV-YD-H |
| Type | Grid-tied hybrid inverter with battery input |
| Rated power (grid output) | 80 kW / 80 kVA |
| Phases / grid voltage | 3/N/PE, 220/380 V or 230/400 V |
| Frequency | 50 Hz / 60 Hz |
| Rated grid output current | 121.6 A / 115.5 A |
| Power factor | >0.99 (0.8 leading – 0.8 lagging) |
| THDi | <3 % |
| Recommended max. PV array power | 160 kW |
| Max. input voltage | 1000 V |
| MPPT voltage range | 150–950 V |
| Max. input current / max. short-circuit current (per MPPT) | 42 A / 60 A |
| Number of MPPTs / strings | 10 / 20 |
| Battery type | Li-ion, high voltage (HV) |
| Battery voltage range | 300–950 V |
| Battery ports | 2, each 100 A charge / 100 A discharge |
| Max. charge / discharge current | 2 × 100 A / 2 × 100 A |
| Fast charging current | Up to 200 A |
| Compatible battery modules | 100–314 Ah |
| Backup output power | 80 kW |
| Backup overload | 1.6 × rated power for 10 s, 2 × rated power for 200 ms |
| Switchover time to backup | <10 ms |
| Max. power per phase (grid and backup) | 26.66 kW |
| Max. permitted phase imbalance | 100 % |
| Generator input: max. power / rated current | 80 kW / 121.6 A / 115.5 A |
| Max. efficiency | 97.5 % |
| Protections | Anti-islanding, insulation resistance monitoring, overcurrent, short circuit, overvoltage, reverse DC polarity, surge protection (DC type II / AC type II), AFCI 2.0 |
| Protection class / overvoltage category | I; DC II, AC III |
| Topology | Transformerless |
| Dimensions (W × H × D) | 1174 × 814 × 400 mm |
| Weight | 170 kg |
| Ingress protection | IP66 |
| Operating temperature | −25 to +60 °C |
| Relative humidity | 0–100 % |
| Noise (typical) | <70 dB(A) |
| Cooling | Smart redundant fan cooling |
| Max. operating altitude | 3000 m |
| Connectors | PV: MC4; battery: terminals; AC: terminal block |
| Display | 7.0″ LCD, Bluetooth + app |
| Communication | CAN, RS485, Ethernet; optional Wi-Fi, cellular, LAN |
| Parallel operation | Up to 6 units, up to 1.25 MW |
| Grid connection standards | G99, VDE-AR-N 4105 / VDE V 0124, EN 50549-1 and -2, EN 50549-10 and others |
| Safety and EMC standards | IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-4, EN 55011 |
| Mounting | Wall or frame |
| Warranty | 5 years, extendable to 20 years |
What is an 80 kW three-phase hybrid inverter used for?
The Solis S6-EH3P80K10-NV-YD-H is meant for factories, warehouses, farms and shopping centres where a solar PV system works together with a high-voltage battery. It has 10 independent MPPT trackers and 20 string inputs, so groups of panels can have different tilt and orientation: each runs at its own operating point and does not drag the others down.
- The recommended maximum PV array power is 160 kW.
- The MPPT voltage range is 150–950 V and the maximum input voltage is 1000 V.
- The maximum input current is 42 A per MPPT.
Hybrid inverter with battery: which batteries fit?
The Solis S6-EH3P80K10-NV-YD-H connects only to high-voltage (HV) Li-ion batteries of 300–950 V, and the compatible battery modules are 100–314 Ah. The inverter has two battery ports, each allowing 100 A charge and 100 A discharge current, and the fast charging current reaches up to 200 A.
From our range, this is the high-voltage EASYWAY UNIV-HV series. We check compatibility before you order.
Backup power during a grid outage
The Solis S6-EH3P80K10-NV-YD-H has an 80 kW backup output and switches the site to island operation in less than 10 ms. Backup overload is up to 1.6 × rated power for 10 s and up to 2 × rated power for 200 ms. The maximum power per phase is 26.66 kW, and the permitted phase imbalance is up to 100 %.
The generator input accepts a maximum of 80 kW. The manufacturer also lists other combinations: DC and AC coupling, photovoltaics, wind and a diesel generator.
How the S6-EH3P80K10-NV-YD-H differs from the other S6-EH3P80–125K10 models
| Parameter | 80 kW | 100 kW | 125 kW |
|---|---|---|---|
| Rated grid and back-up power | 80 kW | 100 kW | 125 kW |
| Rated grid output current | 121.6 / 115.5 A | 151.9 / 144.3 A | 189.9 / 180.4 A |
| Recommended maximum PV array power | 160 kW | 200 kW | 250 kW |
| Maximum power per phase | 26.66 kW | 33.33 kW | 41.66 kW |
| Back-up overload | 1.6× rated power for 10 s; 2× for 200 ms | 1.6× rated power for 10 s; 2× for 200 ms | 1.4× rated power for 10 s; 1.6× for 200 ms |
Choose the S6-EH3P80K10-NV-YD-H when 80 kW of grid and back-up output is enough and the PV array stays within 160 kW. If you need more power, look at the Solis S6-EH3P100K10-NV-YD-H: 100 kW and a PV array of up to 200 kW. All three models have 10 MPPT trackers and two battery ports, and all switch to back-up in under 10 ms.
Dimensions, weight (170 kg), IP66, the 300–950 V battery range and the other parameters are the same on all three models. Up to 6 units can run in parallel, up to 1.25 MW. We size the power from your service connection, consumption and storage capacity.
Grid connection, ESO and installation
The Solis S6-EH3P80K10-NV-YD-H connects to a three-phase grid (3/N/PE), and an 80 kW generation and storage installation must be registered with ESO. The manufacturer lists the grid connection standards G99, VDE-AR-N 4105 and EN 50549-1 and -2. A hybrid inverter lets you keep part of the surplus on site. ESO (Lithuanian grid operator) states:
“Part of the surplus electricity generated can be stored in an energy storage device and used in the evening.”
We handle it for you. We select the equipment for your site, deliver anywhere in Lithuania, install and connect it. The consultation before purchase is free.
What to know before buying
- Batteries: high-voltage Li-ion only, 300–950 V.
- Weight and dimensions: 170 kg, 1174 × 814 × 400 mm, mounted on a wall or frame.
- Environment: IP66, operating temperature from −25 to +60 °C, operating altitude up to 3000 m.
- Noise: typical level below 70 dB(A), fan cooling.
- Control: 7.0″ LCD display, Bluetooth and app; communication CAN, RS485, Ethernet, optional Wi-Fi and cellular; monitoring through SolisCloud.
- Warranty: the manufacturer’s manual states 5 years, extendable to 20 years.
Frequently asked questions
What is the rated power of the Solis S6-EH3P80K10-NV-YD-H and how many phases does it have?
The Solis S6-EH3P80K10-NV-YD-H has a rated grid output power of 80 kW (80 kVA) and works on a three-phase grid, 3/N/PE, 230/400 V or 220/380 V. The rated output current is 121.6 A / 115.5 A.
Which batteries can be connected to the Solis S6-EH3P80K10-NV-YD-H?
The Solis S6-EH3P80K10-NV-YD-H connects only to high-voltage Li-ion batteries of 300–950 V with modules of 100–314 Ah. From our range the EASYWAY UNIV-HV series fits, and we check compatibility before you order.
How many battery ports does the Solis S6-EH3P80K10-NV-YD-H have?
The Solis S6-EH3P80K10-NV-YD-H has 2 battery ports, each allowing 100 A charge and 100 A discharge current. The fast charging current reaches up to 200 A.
Can the Solis S6-EH3P80K10-NV-YD-H power a site during a grid outage?
Yes, the Solis S6-EH3P80K10-NV-YD-H has an 80 kW backup output and switches to island operation in less than 10 ms. Backup overload is up to 1.6 × rated power for 10 s and up to 2 × rated power for 200 ms.
How much PV power can be connected to the Solis S6-EH3P80K10-NV-YD-H?
The manufacturer recommends up to 160 kW of PV array power, and the Solis S6-EH3P80K10-NV-YD-H has 10 MPPT trackers and 20 string inputs. The maximum input voltage is 1000 V and the MPPT range is 150–950 V.
Can the Solis S6-EH3P80K10-NV-YD-H be connected in parallel?
Yes, the manufacturer allows up to 6 such units in parallel, up to 1.25 MW in total. Hybrid Energy selects the number of inverters to match your site’s load.
Can a diesel generator be connected to the Solis S6-EH3P80K10-NV-YD-H?
Yes, the Solis S6-EH3P80K10-NV-YD-H has a generator input with a maximum power of 80 kW. The manufacturer lists combinations with photovoltaics, wind and a diesel generator.
What warranty does the Solis S6-EH3P80K10-NV-YD-H have?
The manufacturer’s manual states a 5-year warranty for the Solis S6-EH3P80K10-NV-YD-H, extendable to 20 years.
Can the Solis S6-EH3P80K10-NV-YD-H be installed outdoors?
The Solis S6-EH3P80K10-NV-YD-H has an IP66 ingress rating and works from −25 to +60 °C. It is mounted on a wall or frame and weighs 170 kg.
Does Hybrid Energy install and connect the Solis S6-EH3P80K10-NV-YD-H?
Yes, Hybrid Energy delivers the Solis S6-EH3P80K10-NV-YD-H anywhere in Lithuania, installs and connects it. An 80 kW installation must be registered with ESO, and the consultation before purchase is free.