The Marsun MVD12 is a three-phase 230 V / 400 V diesel generator in a sound-insulating canopy, rated 11 kW (12 kW maximum) with equal power on each phase, so the full output is available from a single-phase 230 V socket too. Next to the MVD15 it is the smaller and 11 kg lighter (253 kg) option, and it suits a home, farm or building site with a continuous load up to about 8.3–8.8 kW (75–80% of rated power); at the full 11 kW the 25 l tank lasts about 5.6 h. For automatic start from a hybrid inverter or ATS it has a Two-Wire Switch connection.

Technical specifications

Parameter Value
Model MVD12
Fuel diesel
Cooling air
Rated power 11 kW
Maximum power 12 kW
Rated voltage 230 V / 400 V
Frequency 50 Hz
Phases three-phase
Equal power on each phase yes
Engine model 2V88
Engine type 2-cylinder, 4-stroke, air-cooled
Displacement 912 cm³
Engine speed 3600 rpm
Recommended engine oil 15W-40
Oil quantity 2.8 l
Noise level 74 dB
Continuous run time (manufacturer figure, load not stated) 12 h
Fuel consumption 340 g/kWh
Fuel tank capacity 25 l
Weight 253 kg
Dimensions (L × W × H) 1200 × 675 × 885 mm
Start electric (key)
Sound-insulating canopy yes
Windings copper
Voltage regulation (AVR) yes
ATS optional, external module sold separately
Two-Wire Switch connection yes
Remote parameter monitoring (Modbus) no
Heated fuel unit no
Automatic shutdown at 10% fuel no

Download the manufacturer datasheet (PDF)

How the MVD12 differs from the MVD15

Both generators have the same 25 l tank, the same sound-insulating enclosure, 74 dB noise level, 340 g/kWh fuel consumption, 230 V / 400 V output and 1200 × 675 × 885 mm dimensions; the differences are power, engine and the consumption that follows from them.

Parameter MVD12 MVD15
Rated / maximum power 11 / 12 kW 14 / 15 kW
Recommended continuous load (75–80% of rated power) 8.3–8.8 kW 10.5–11.2 kW
Engine 2V88, 912 cm³, 3600 rpm 2V92, 997 cm³, 3000 rpm
Fuel use and 25 l tank run time at full rated load (calculated) 4.45 l/h, about 5.6 h 5.67 l/h, about 4.4 h
Continuous run time stated by the manufacturer (load not stated) 12 h 8 h
Weight / oil quantity 253 kg / 2.8 l 264 kg / 3.5 l

Choose the MVD12 if your continuous load stays below about 8.3–8.8 kW: it is lighter, takes less oil, and at full load the 25 l tank lasts longer. If you expect to draw 10.5–11.2 kW or more on a regular basis, take the Marsun MVD15 with 14 kW of rated power.

What is an 11 kW diesel generator used for: home, farm and building sites

  • Backup power for a house and a farm
  • Supporting a solar PV system with energy storage
  • Powering a building site
  • Powering a workshop
  • A garden plot, camping and outdoor events

How much fuel does the MVD12 use and how long does it run on a full tank?

The manufacturer states fuel consumption of 340 g/kWh. At the full 11 kW rated load that is 340 × 11 / 1000 = 3.74 kg of diesel per hour, or 3.74 / 0.84 ≈ 4.45 l/h. At that rate the 25 l tank lasts about 5.6 h (25 / 4.45). This is an indicative calculation.

The manufacturer states 12 h of continuous running but does not say at what load that time is reached. Real run time depends on the load: the lower the load, the less fuel is used per hour, so the tank lasts longer.

How do you start the generator automatically from a hybrid inverter or ATS?

The MVD12 has a factory Two-Wire Switch connection (a dry, voltage-free contact). It is a simple two-wire connection through which a hybrid inverter or an ATS cabinet automatically starts and stops the generator without your involvement.

  • With a hybrid or off-grid inverter the generator is connected to the inverter’s generator input, and the inverter decides on its own when the generator is needed. When solar production is too low and the storage is flat, the generator takes over powering the loads and charging the batteries.
  • In a system with an inverter, a separate ATS cabinet is not needed.
  • At a site without a solar PV system, an ATS cabinet monitors the grid and starts the generator when the voltage drops. This model has no built-in ATS; an external ATS module is bought separately.

When the contact of the connection is closed, the start procedure begins, and when it is opened, the engine shuts down safely. The manufacturer states compatibility with Deye, Solis, Solplanet, GoodWe, Victron Energy and Sungrow hybrid inverters. Connecting to the building’s installation and configuring the ATS must be done by a certified electrician.

How do you connect a backup generator to a house?

The generator is connected to the site’s internal network through a fixed connection. It has a connection for an external ATS module, so changeover can be automated; the module is bought separately, and there is no built-in ATS in this model. ESO (Lithuanian grid operator) states:

“A generator may be connected to the internal electrical network of a whole building only by installing a fixed connection and measures that ensure the voltage produced by the generator is not fed into ESO’s networks… Entrust this work only to qualified specialists.”

ESO — Recommendations for installing a backup power source

The same ESO page advises choosing the power according to your supply connection and, when connecting single-phase loads to a three-phase generator, checking the limit of one phase, because the datasheet gives the total power of all three phases.

We handle it for you. We select the equipment for your site, deliver anywhere in Lithuania, install and connect it.

Equal power on each phase: three-phase and single-phase loads from one generator

The manufacturer states that from the single-phase socket of an ordinary three-phase generator only a third of the total power can be used. The MVD12 has equal power on each phase, so the generator’s power can be used both through the three-phase 400 V socket and through the single-phase 230 V socket.

Allow for starting currents: inductive loads such as pumps and compressors draw 2–5 times more current at the moment of starting than when running.

Running at full 100% power for long periods is not recommended. The optimum for the engine and generator is 75–80% of rated power, for the MVD12 about 8.3–8.8 kW (a 25% power reserve). If the system has energy storage, add the power the generator will use to charge the batteries to the building’s demand.

What to know before buying

  • Noise and canopy. The generator comes in a sound-insulating canopy and the manufacturer states 74 dB. It is still a diesel engine, so plan the location, ventilation and fuel storage in advance.
  • Weight and size. The MVD12 weighs 253 kg and measures 1200 × 675 × 885 mm.
  • Oil. The generator is delivered without engine oil. Before the first start add 2.8 l of 15W-40 oil.
  • Fuel. Diesel. This model has no heated fuel unit, no automatic shutdown at 10% fuel and no Modbus monitoring.
  • Protection. No-load protection, overpressure protection, an overcurrent circuit breaker, AVR voltage regulation, and a frequency and voltage indicator.

Frequently asked questions

How long does the Marsun MVD12 run on a full tank?

The manufacturer states 12 h of continuous running with the 25 l tank but does not state the load. Our indicative calculation for the full 11 kW load is about 5.6 h, because consumption is then about 4.45 l/h.

How much fuel does the MVD12 generator use?

The manufacturer states 340 g/kWh; at 11 kW load that is about 3.74 kg, or 4.45 l of diesel per hour. At a lower load, consumption per hour is lower.

Does the Marsun MVD12 have ATS?

No, the MVD12 has no built-in ATS, but it has a Two-Wire Switch connection for an external ATS module, which is bought separately. In a system with a hybrid inverter a separate ATS is not needed.

Which inverters is the MVD12 compatible with?

The manufacturer states Deye, Solis, Solplanet, GoodWe, Victron Energy and Sungrow hybrid inverters. Automatic starting works through the Two-Wire Switch connection, and Hybrid Energy matches the exact scheme to your inverter model.

Can the MVD12 be connected straight to the house fuse board?

Not directly: the MVD12 is connected to the house network only through a fixed connection with protection so that voltage cannot reach the ESO grid, and only qualified specialists may connect it. Feeding power back into the house through a plug and socket is dangerous and not permitted.

Is the 11 kW MVD12 generator suitable for a house, farm or building site?

Yes, the manufacturer intends the MVD12 for home and farm backup power, building sites, workshops and solar PV systems with storage. Hybrid Energy selects the power according to your supply connection and real load.

How loud is the MVD12?

The manufacturer states a noise level of 74 dB and the generator comes in a sound-insulating canopy. The distance at which it was measured is not stated, so it is worth planning the location in advance.

How does the MVD12 differ from the MVD15?

The MVD12 is rated 11 kW and the MVD15 14 kW; the recommended continuous load is 8.3–8.8 kW and 10.5–11.2 kW respectively. The MVD12 weighs 253 kg and the MVD15 264 kg; both have a 25 l tank, but at full rated load it lasts about 5.6 h and about 4.4 h.

What is the optimum load for the MVD12?

About 8.3–8.8 kW, i.e. 75–80% of rated power; running at 100% for long periods is not recommended. Pumps and compressors draw 2–5 times more current when starting, which must also be allowed for.

Is the MVD12 delivered with oil?

No, the MVD12 is delivered without oil: before the first start add 2.8 l of 15W-40 oil. Hybrid Energy delivers anywhere in Lithuania, installs it and puts it into operation.