Tinklaraštis
Advice on choosing equipment: power, compatibility, subsidies and running costs.
What size heater do I need for a warehouse, hall or building site?
You size a heater for a warehouse, hall or building site by the room volume:
length × width × height. The EMLO manufacturer states that the 13 kW heater is
meant for rooms up to 900 m³, the 16 kW for up to 1100 m³, the 20 kW for up
to 1400 m³ and the 29 kW for up to 2000 m³. That is roughly 69 m³ per
kilowatt. We are Hybrid Energy, a Lithuanian shop: we sell EMLO diesel infrared
heaters, Termofol electric infrared heaters and heat pumps, so we do not push any one
of them. We deliver across Lithuania.
Key points
- The manufacturer links EMLO heater output to volume (m³), not to
floor area (m²). Two warehouses with the same floor area but 4 m and 6 m ceilings
differ in volume by half as much again, so they may need different models. - The manuals for the EMLO 13, 16, 20 and the DC series allow them only in rooms with
a floor area of at least 80 m². Smaller workshops and garages are
better served by electric infrared heaters. - Maximum consumption ranges from 0.2–0.75 l/h (EMLO DC 8) to 2.37–2.64 l/h
(EMLO 29). Cost per hour = consumption in l/h × diesel price in €/l. At the average
diesel price of €2.249 per litre on 6 November 2026 (LEA), an hour costs from
€0.45–1.69 (EMLO DC 8) to €5.33–5.94 (EMLO 29); diesel prices change. - One tank lasts 17.3–65 hours, depending on the model and setting. Hours = tank
capacity ÷ consumption per hour. The calculation is in the table below. - The DC series also runs for up to 8 hours on a 24 V battery, so it suits sites
with no mains power yet. But its tank is smaller and its price higher: the EMLO DC 16
costs €1,799 with a 45 l tank, the mains-powered EMLO 16 €1,699 with 50 l.
All 7 EMLO models: room volume, price, fuel consumption and tank
The table lists all seven EMLO models we sell. Room volume (m³) follows the
manufacturer’s data. We calculated how many hours one tank lasts by dividing the tank
capacity by the maximum consumption stated by the manufacturer. Prices are our shop
prices as of 8 November 2026.
| Model | Room volume (manufacturer’s data) | Output | Price | Consumption | Tank | Hours per tank | Power supply |
|---|---|---|---|---|---|---|---|
| EMLO DC 8 | up to 550 m³ | 2–8 kW (adjustable) | €1,299 | 0.2–0.75 l/h | 13 l | 13 ÷ 0.75 = 17.3 h; 13 ÷ 0.2 = 65 h | 220–240 V or 24 V 8 Ah battery, up to 8 h |
| EMLO 13 | up to 900 m³ | 13 kW | €1,599 | 0.95–1.14 l/h | 50 l | 50 ÷ 1.14 = 43.9 h; 50 ÷ 0.95 = 52.6 h | 220–240 V, 80 W |
| EMLO 16 | up to 1100 m³ | 16 kW | €1,699 | 1.18–1.45 l/h | 50 l | 50 ÷ 1.45 = 34.5 h; 50 ÷ 1.18 = 42.4 h | 220–240 V, 80 W |
| EMLO DC 16 | up to 1100 m³ | 16 kW | €1,799 | 1.18–1.45 l/h | 45 l | 45 ÷ 1.45 = 31.0 h; 45 ÷ 1.18 = 38.1 h | 220–240 V or 24 V 16 Ah battery, up to 8 h |
| EMLO 20 | up to 1400 m³ | 20 kW | €2,199 | 1.40–1.60 l/h | 70 l | 70 ÷ 1.60 = 43.8 h; 70 ÷ 1.40 = 50 h | 220–240 V, 80 W |
| EMLO DC 20 GARDEN | up to 1400 m³ | 20 kW | price on request | 1.57–1.82 l/h | 35 l | 35 ÷ 1.82 = 19.2 h; 35 ÷ 1.57 = 22.3 h | 220–240 V or 24 V DC battery, up to 8 h |
| EMLO 29 | up to 2000 m³ | 29 kW | €2,699 | 2.37–2.64 l/h | 70 l | 70 ÷ 2.64 = 26.5 h; 70 ÷ 2.37 = 29.5 h | 230 V, 80 W |
The EMLO DC 8 has a wide consumption range because its output can be set anywhere
from 2 to 8 kW. It will run 65 hours on one tank only at the lowest setting, not at
full power.
How to calculate the room volume
Room volume = length × width × height in metres, and the result is in cubic metres.
Compare this figure with the manufacturer’s volume in the table and choose a model
whose limit is above your room volume. Work out the floor area (length × width)
separately: it tells you whether the room meets the 80 m² requirement.
Three examples with made-up dimensions (an illustration, not a calculation for a
real building):
- Warehouse 24 × 12 m, 4 m ceiling. Volume 24 × 12 × 4 =
1152 m³, floor area 288 m². 1152 m³ is above the EMLO 16 limit (1100 m³)
but within the EMLO 20 limit (1400 m³). - The same warehouse, 6 m ceiling. Volume 24 × 12 × 6 =
1728 m³. The floor area has not changed, but the volume is now above the EMLO 20
limit, so the EMLO 29 fits (up to 2000 m³). - Workshop 12 × 8 m, 3.5 m ceiling. Volume 12 × 8 × 3.5 =
336 m³, floor area 96 m². The volume is within the EMLO DC 8 limit (up to
550 m³), and the floor area is above 80 m².
A 6 × 4 m garage has a floor area of 24 m², which is less than 80 m², so we
do not offer an EMLO diesel heater for it: electric infrared heaters suit a room like
that (see below).
How insulation and ceiling height change the output you need
The manufacturer’s volume is a reference point, not a guarantee for any building.
EMLO states average consumption under specific test conditions: an insulated
500 m³ room, 15 °C inside and 0 °C outside, 8 hours of operation. In an
uninsulated hall, a building under construction without windows, or a place where the
doors are opened often, conditions are very different.
Insulation. Heat lost through walls, roof and doors has to be
replaced all the time, so in a poorly insulated building the heater runs longer at
higher output. Exactly how much depends on the building, and the manufacturer gives
no correction factor. The practical takeaway: if your room volume is close to a
model’s limit and the building is uninsulated, choose the next model up.
Ceiling height. Volume grows in proportion to height: for the
same floor area, a room with a 6 m ceiling has half as much volume again as one
with a 4 m ceiling. The manual also requires a clearance: the EMLO 13, 16 and 20
must stand at least 1 m from the ceiling. The EMLO 13 is 935 mm high, so the
ceiling must be at least 0.935 + 1 = 1.935 m; the EMLO 16 and 20 are 1110 mm
high, so the ceiling must be at least 2.11 m.
How the heater spreads heat. The EMLO burner heats a
ceramic-coated tube, and the heat travels as radiation. So place the heater where
people work, not in a corner behind the racking.
Diesel heater fuel consumption per hour: what an hour of heating costs
Cost per hour: consumption in l/h × diesel price in €/l. The
table uses the average Lithuanian diesel price of €2.249 per litre
(LEA data, 6 November 2026). Prices change, so check the day’s price at your filling
station before you plan a budget. EMLO heaters run on diesel or kerosene, and the
manufacturer also mentions biodiesel and HVO.
| Model | Maximum consumption | Cost per hour at maximum consumption (€2.249/l) | Average consumption (manufacturer’s test) | Cost per hour at average consumption |
|---|---|---|---|---|
| EMLO DC 8 | 0.2–0.75 l/h | €0.45–1.69 | — | — |
| EMLO 13 | 0.95–1.14 l/h | €2.14–2.56 | ~0.31 l/h | ~€0.70 |
| EMLO 16 | 1.18–1.45 l/h | €2.65–3.26 | ~0.38 l/h | ~€0.85 |
| EMLO DC 16 | 1.18–1.45 l/h | €2.65–3.26 | — | — |
| EMLO 20 | 1.40–1.60 l/h | €3.15–3.60 | ~0.48 l/h | ~€1.08 |
| EMLO DC 20 GARDEN | 1.57–1.82 l/h | €3.53–4.09 | — | — |
| EMLO 29 | 2.37–2.64 l/h | €5.33–5.94 | ~0.70 l/h | ~€1.57 |
Shift example: an EMLO 20 runs for 8 hours at maximum consumption (1.60 l/h).
That is 1.60 × 8 = 12.8 l of fuel, or 12.8 × 2.249 = €28.79 per shift. Under the
same conditions the EMLO 29 uses 2.64 × 8 = 21.12 l, or €47.50.
Under the manufacturer’s test conditions (insulated 500 m³ room, 15 °C inside,
0 °C outside), average consumption is much lower. Then the EMLO 20 would use
0.48 × 8 = 3.84 l (€8.64) over an 8-hour shift and the EMLO 29 0.70 × 8 = 5.6 l
(€12.59), and the 70 l EMLO 20 tank would last 70 ÷ 0.48 = 145.8 hours. Plan your
budget on maximum consumption and treat the average figures as the best case in an
insulated building.
Safety requirements: where you can use a diesel infrared heater
Some options are ruled out not by price but by the requirements of the manual. It
is worth checking them before you choose the output.
Floor area of at least 80 m². The manuals for the EMLO 13, 16,
20 and the DC series allow the heater only in rooms with a floor area of at least
80 m². The fuel burns in the room itself and no chimney is provided, so the amount
of air and how often it is replaced are a safety condition. The manufacturer intends
the EMLO 29 for large, well-ventilated spaces.
Regular ventilation. Large rooms do not need a chimney, but the
room must be aired regularly through a window or with a fan. The manual explains why:
when oxygen runs short, more carbon monoxide forms. The DC series manual gives a
specific requirement: replace the room air with fresh air 6 times per hour. In tighter
spaces the combustion gases are taken out through an aluminium pipe: EMLO 13, 16, 20
and DC 16 – Ø100 mm × 5 m, DC 8 – Ø75 mm × 2 m.
Clearances and fire extinguisher. According to the EMLO 13, 16 and
20 manual, the heater must stand at least 15 cm from a wall and at least 1 m from
the ceiling and in front; keep a fire extinguisher nearby. The heater is intended for
production halls, warehouses, workshops, garages, building sites and tents, and the
manual forbids using it in bedrooms, in small closed rooms and while sleeping.
Smell. When the heater is switched off, an electromagnetic by-pass
valve returns the leftover fuel to the tank, so, in the manufacturer’s words, the fuel
smell is noticeably reduced. According to EMLO, a brief smell at start-up is normal,
and a constant smell usually points to a fuel or filter problem.
Safety systems. The EMLO 13, 16 and 20 have two-stage overheating
protection, flame monitoring, a shock and tilt sensor and a low-fuel warning. The DC
series has overheating protection, flame monitoring, shut-off if tipped over, a child
lock, a 24-hour timer and fuel pre-heating below 5 °C.
When to choose the EMLO 13, 16, 20 or 29
A mains-powered EMLO suits a warehouse, hall or workshop with a 230 V socket. The
EMLO 13, 16 and 20 manual requires a floor area of at least 80 m², and the
manufacturer intends the EMLO 29 for large, well-ventilated spaces. The heater itself
uses only 80 W of electricity and makes its heat from diesel or kerosene, so even a
large room does not need a three-phase supply. You can control the heater with the
TERMOFOL Smart app (iOS, Android, Wi-Fi 2.4 GHz) or a remote.
What to consider. Fuel logistics: the 50–70 l tanks need
refilling and the fuel has to be stored somewhere. Weight: from 45 kg (EMLO 13) to
79.5 kg (EMLO 29), which matters if you move the heater from site to site. And
constant ventilation, which lets some of the heat escape.
When to choose the EMLO DC series
The DC series suits a building site or property where there is no mains power yet,
or it is unreliable: the heater runs on a 220–240 V supply or for up to 8 hours on
a 24 V battery. It does not run directly from a 12 V car socket.
What to consider. A DC model of the same output costs more and has
a smaller tank: the EMLO DC 16 costs €1,799 with a 45 l tank, the EMLO 16 €1,699
with a 50 l tank. The EMLO DC 8 tank (13 l) lasts 17.3 hours at full power, so
on longer jobs you will have to top up the fuel daily.
When to choose an electric infrared heater
For rooms smaller than 80 m², and wherever you do not want fuel burning in the
room, we offer Termofol electric infrared heaters:
TF-IR1600
(1600 W, €399),
TF-IR2400
(2400 W, €299) and
TF-IR3200
(3200 W, €349). We cover their output and cost in more detail in our article on
infrared heating power and running cost.
What to consider. No fuel is needed, but an infrared heater uses as
much electricity per hour as its rated output: the TF-IR3200 at full power uses
3.2 kWh per hour. That will show on your electricity bill.
Frequently asked questions
What size heater do I need for a 1000 m³ warehouse?
Per the manufacturer’s data, a 1000 m³ warehouse suits the EMLO 16, rated for rooms up to 1100 m³. If the warehouse is uninsulated or the doors open often, Hybrid Energy suggests also considering the EMLO 20, rated for up to 1400 m³. The floor area must be at least 80 m², and the room must be aired regularly.
How much fuel does a 20 kW diesel heater use per hour?
The EMLO 20 uses at most 1.40–1.60 l/h, so at full power its 70 l tank lasts
43.8–50 hours. At the average diesel price of €2.249 per litre on 6 November 2026
(LEA), an hour costs €3.15–3.60. Under the manufacturer’s test conditions (insulated
500 m³ room), average consumption is about 0.48 l/h, or about €1.08 per
hour.
Can you use a diesel infrared heater on a construction site?
Yes. The manufacturer intends EMLO heaters for large, well-ventilated spaces: production halls, warehouses, workshops, garages, building sites and tents. The EMLO 13, 16, 20 and DC series manuals require a floor area of at least 80 m², regular ventilation and a fire extinguisher. On a closed floor of a building under construction, Hybrid Energy recommends planning ventilation in advance.
Can a diesel heater run without mains power?
The EMLO DC series can: the DC 8 on a 24 V 8 Ah battery, the DC 16 on 24 V 16 Ah, up to 8 hours. Neither runs directly from a 12 V car socket. The EMLO 13, 16, 20 and 29 need a 230 V supply and draw 80 W. Hybrid Energy recommends DC for off-grid sites.
Is a diesel heater suitable for a house or small garage?
The EMLO is made for large rooms: the manual forbids it in bedrooms, small closed rooms and while sleeping, and the EMLO 13, 16, 20 and DC series must not be used in rooms under 80 m². For a house, Hybrid Energy suggests a heat pump or electric infrared panels; for a small garage, Termofol electric infrared heaters from €299.
Let us help you choose a heater
Send us four details: the length, width and ceiling height of the room in metres;
whether the building is insulated; whether there is a 230 V socket on site; and how
many hours a day you need heating. Based on these, we will advise which EMLO model or
electric infrared heater fits and how much fuel one shift will take. Email
sales@hybridenergy.lt or call +370 636 52 222. We deliver across Lithuania.
Sources
- EMLO 13/16/20 user manual (PL): 80 m² limit, ventilation, clearances, fire extinguisher, flue pipe, safety features, by-pass valve:
emlo.com.pl (accessed 8 November 2026) - EMLO DC-08 user manual (PL/EN/DE); declaration of conformity 03/CE/2026 covers DC-08, DC-16 and DC-20-GARDEN: 24 V power supply, ventilation 6 times per hour, safety features:
termofol.pl (accessed 8 November 2026) - Termofol liquid-fuel heater catalogue: DC series volumes in m³, average consumption test conditions:
termofol.pl (accessed 8 November 2026) - Termofol, EMLO DC 16 page: volume, flue pipe:
termofol.pl (accessed 8 November 2026) - Termofol, EMLO 29 page: intended for large, well-ventilated spaces:
termofol.pl (accessed 8 November 2026) - EMLO: EMLO 13–29 volumes in m³, average consumption, fuel types:
emlo.com.pl; FAQ on start-up smell:
emlo.com.pl (accessed 8 November 2026) - Average diesel price in Lithuania on 6 November 2026: €2.249 per litre, Lithuanian Energy Agency (LEA) data:
pigiausidegalai.lt (accessed 8 November 2026) - Hybrid Energy, EMLO and Termofol product pages: prices:
hybridenergy.lt (accessed 8 November 2026)