The Eastron SDM630-Modbus V3 (MID) is a three-phase energy meter with Modbus RTU (RS485) communication for 1p2w, 3p3w and 3p4w networks. It measures voltage, current, power, and imported and exported energy, and up to 100 A it needs no current transformers. Active energy accuracy is class 1 (IEC 62053-21); it mounts on a DIN rail and suits solar installers and energy management system (EMS) integrators.
Technical specifications
| Parameter | Value |
|---|---|
| Model | SDM630-Modbus V3 (MID) |
| Supported systems | 1p2w, 3p3w, 3p4w |
| Measured parameters | voltage (V), frequency (Hz), current (A), power (kW/kVA/kVar), imported and exported energy, total energy (kWh/kVarh) |
| Maximum demand | current and power peaks, intervals programmable up to 60 min |
| Nominal AC voltage (Un) | 3×230(400) V |
| Voltage range | 80–120% Un |
| Base current (Ib) | 10 A |
| Maximum current (Imax) | 100 A |
| Minimum current (Imin) | 0.5 A |
| Starting current | 0.4% Ib |
| Current transformers | not needed (direct connection up to 100 A) |
| Own consumption | ≤ 2 W / 10 VA (voltage circuit); ≤ 4 VA (current circuit) |
| Voltage accuracy | 0.5% of maximum range |
| Current accuracy | 0.5% of nominal |
| Frequency accuracy | 0.2% of mid frequency |
| Power factor accuracy | 1% of unity (0.01) |
| Active / reactive / apparent power accuracy | ±1% of maximum range |
| Active energy | class 1, IEC 62053-21 |
| Reactive energy | ±1% of maximum range |
| Response time | 1 s (step signal, typically >99% of final reading, 50 Hz) |
| Communication | Modbus RTU (RS485) |
| Mounting | DIN rail to DIN 43880, 72 × 100 mm (width × height) |
| Protection | IP51 (indoor) |
| Operating temperature | -25 °C … +55 °C |
| Storage temperature | -40 °C … +70 °C |
| Relative humidity | 0–95%, non-condensing |
| Operating altitude | up to 2000 m above sea level |
| Vibration | 10–50 Hz, 2 g, IEC 60068-2-6 |
| Shock | 30 g |
| Case material | self-extinguishing plastic UL94 V-0 |
| Pulse constant | 400 imp/kWh |
| MID | “MID” in the model name, catalogue marking 2,5-10 (100A) |
Download the manufacturer datasheet (PDF)
What is a three-phase Modbus energy meter used for?
- Solar installers
- Monitoring energy consumption and generation
- Integration with energy management systems (EMS) over Modbus RTU (RS485)
- Controlling current and power peaks: demand intervals are programmable up to 60 min
What does an energy meter for a solar plant measure?
The SDM630-Modbus V3 (MID) measures voltage, frequency, current, power (kW, kVA, kVar) and energy (kWh, kVarh), including imported and exported energy. Active energy is class 1 to IEC 62053-21, voltage and current accuracy are 0.5% each, and response time is 1 s.
Does it need current transformers, and what current can it take?
This meter connects directly up to 100 A, so no current transformers are needed. Base current is 10 A, maximum 100 A, minimum 0.5 A, and starting current 0.4% Ib. If the current at your site is higher, we will choose a suitable solution.
Installation and conditions
The meter mounts on a DIN rail to DIN 43880 and measures 72 × 100 mm. Protection class IP51 is for indoor installation, operating temperature is -25 °C to +55 °C, and altitude is up to 2000 m above sea level. The case is made of self-extinguishing plastic UL94 V-0.
Hybrid Energy can help you choose. Tell us which network and EMS you use, and we will check that the SDM630-Modbus V3 suits your system and deliver it anywhere in Lithuania.
What to know before buying
- Communication: Modbus RTU (RS485). The manufacturer’s datasheet has no list of specific inverters or EMS, so we check compatibility before you buy.
- MID: the model name includes “MID”, with catalogue marking 2,5-10 (100A).
- Network: 1p2w, 3p3w or 3p4w, nominal voltage 3×230(400) V, range 80–120% Un.
- Own consumption: ≤ 2 W / 10 VA in the voltage circuit and ≤ 4 VA in the current circuit.
Frequently asked questions
Does the SDM630-Modbus V3 (MID) need current transformers?
No. The Eastron SDM630-Modbus V3 (MID) connects directly up to 100 A. Minimum measured current is 0.5 A and maximum is 100 A.
How does the SDM630-Modbus V3 connect to an EMS?
The Eastron SDM630-Modbus V3 sends data over Modbus RTU (RS485). This lets you integrate it into energy management systems (EMS).
Is this meter suitable for a three-phase network?
Yes. The Eastron SDM630-Modbus V3 supports single-phase two-wire (1p2w) and three-phase three-wire (3p3w) and four-wire (3p4w) networks. Nominal voltage is 3×230(400) V.
What is the accuracy class of the SDM630-Modbus V3?
Active energy accuracy is class 1 to IEC 62053-21. Voltage and current accuracy are 0.5% each, and frequency accuracy is 0.2%.
What does MID mean in the SDM630-Modbus V3 name?
In the manufacturer’s datasheet the model is called SDM630-Modbus V3 (MID), with catalogue marking 2,5-10 (100A). Hybrid Energy can help you check whether it fits your case before you buy.
Does the meter measure imported and exported energy?
Yes. The SDM630-Modbus V3 (MID) counts imported, exported and total energy (kWh/kVarh), which helps you monitor solar plant generation and consumption.
How is the SDM630-Modbus V3 mounted?
The Eastron SDM630-Modbus V3 mounts on a DIN rail to DIN 43880 and measures 72 × 100 mm (width × height). Protection class is IP51, so it is for indoor use.
What temperature does the SDM630-Modbus V3 work in?
Operating temperature is -25 °C to +55 °C and storage temperature is -40 °C to +70 °C. Relative humidity is 0–95%, non-condensing.
Can Hybrid Energy help me choose the meter?
Yes. Hybrid Energy helps you check that the meter suits your network and EMS, and delivers anywhere in Lithuania. A consultation before purchase is free.