Why the Kilowatts on a Machine’s Nameplate Don’t Tell You What Generator a Workshop Needs

Metalo apdirbimo dirbtuvės su staklėmis ir atidaryta trifaze elektros skydine

We’re Hybrid Energy — we sell diesel generators, hybrid inverters with
battery storage, solar modules, and systems that combine them. We sell every
option, so we have no reason to defend any one of them. This article won’t
tell you what to buy. It shows why adding up the kilowatts listed on your
machines’ nameplates tells you nothing about your workshop, and what each way
of dealing with that actually costs.

The short version

  • A compressor, welder, or lathe draws far more from the grid at startup
    than its nameplate shows. Without exact figures for your equipment, a
    generator is sized for the single heaviest simultaneous startup, not for the
    sum of every device’s rated power.
  • That same spike can briefly exceed your property’s agreed capacity. ESO
    charges triple the capacity rate for that — normally
    €3.00/kW per month excluding VAT, and €9.00/kW per month once exceeded.
  • The same problem has three different fixes: a bigger generator, a battery
    that covers the missing power for that one moment, or raising your agreed
    capacity through ESO. Each has its own cost, whether in money or otherwise.
  • An AVR (voltage regulator) with a power reserve is a different matter
    entirely: it protects the machine tool and its electronics from voltage
    spikes, but it doesn’t address starting current at all.
  • A workshop that doesn’t account for simultaneous startups ends up
    overpaying either for the generator or for agreed capacity it never uses.

What you’re choosing between

The problem isn’t the generator’s size itself — it’s that you’re sizing it
using the wrong number. The rated power on a machine’s nameplate shows how
much it draws running steadily. It doesn’t show how much it needs the instant
a motor, compressor, or transformer switches on.

Why startup is different. An induction motor (in a
compressor, grinder, or ventilation unit) draws a higher current from the
grid at the moment of starting than it does running steadily. By how much
depends on the specific motor and its starting method, so we won’t give a
general figure without the manufacturer’s data. A transformer-type welder
behaves similarly when striking an arc. The practical takeaway is the same:
a generator that easily carries the sum of all your machines’ rated power can
still fail the one moment two devices start at once.

A diesel generator with ATS or AVR. Our range runs from 5.5 kW (Marsun MVD6, 1 969 €) up to 250 kW (Marsun MHD250, 34 799 €). The Marsun MHD models from 25 kW up have an automatic transfer switch (ATS in our catalogue) built in; the smaller MVD models have an AVR voltage stabiliser and a connector for an external ATS module, for when you want automatic start. An
ATS unit alone costs €199 (compatible with 6–15 kW generators) or €269
(for 20 kW generators). All are three-phase. The manufacturer rates the MVD6 at 5.5 kW nominal and 6 kW maximum power — that’s the manufacturer’s
margin for a brief load fluctuation, not a guarantee the generator will
survive any heavier machine startup.

Battery storage with a hybrid inverter. A battery
connected to a hybrid inverter stores energy and releases it during the
seconds a device starts up. Our catalogue offers such kits from a 5 kW
inverter with a single battery (€1,799) up to a 40 kW high-voltage kit with
several battery modules (€12,899). A battery doesn’t solve a long power
outage — it solves a short spike, after which consumption returns to
normal.

Raising your agreed capacity through ESO. This is an
administrative fix, not a technical one: the property is assigned a higher
agreed capacity so the same peak no longer counts as an overrun. The cost is
that the monthly capacity charge rises in direct proportion to the new agreed
capacity (€3.00/kW/month for every extra kilowatt), and that charge is paid
every month regardless of whether the peak recurs.

The axis the whole choice turns on: not how many
kilowatts are listed on your machines, but how many switch on at the same
time, and how many times a day that happens. Until you’ve worked that out,
any of the three prices will look either too high or too low.

Comparison at a glance

Criterion Bigger generator Battery to shave peaks Raising agreed capacity
What it actually solves Covers the peak during a grid outage Absorbs the peak while the grid is up Lets the peak exist legally, without the triple rate
One-off cost 1 969 €–34 799 € (Marsun MVD6–MHD250) €1,799–12,899 (5–40 kW kits) No equipment to buy, but ESO’s capacity-increase service is a separate paid service — check the fee with ESO
Monthly cost Unchanged after purchase Unchanged after purchase +€3.00/kW/month excluding VAT for every extra kW
Works off-grid Yes, as long as there’s fuel For a limited time, depending on battery capacity No — this is a grid-access question, not a backup one
Runs daily or only during peaks Only during an outage or scheduled work Daily, on every startup Does nothing itself, just raises the ceiling
Maintenance needed Test runs, fuel, oil Almost none None — an administrative step

When the right answer is a bigger generator

A backup generator wins where, when the grid goes down, everything has to
start at once — for example, after an emergency stop you need to start the
compressor, extraction ventilation, and lighting simultaneously. If there’s no
grid at all at that moment, the question isn’t peak size anymore, it’s
whether the generator can survive that starting moment.

A less obvious case is a workshop with several independent machines whose
startups occasionally coincide by chance (a compressor kicks in on a pressure
sensor at the same moment a worker switches on the welder). A generator sized
for the property’s average load may simply fail to survive that coincidence
and trip its protection.

The mechanism: a generator’s power needs a margin above the sum of steady
loads — you can see this in our MVD6 model’s own data, where rated power is 5.5 kW and maximum is 6 kW. The more simultaneous startups you expect, the
bigger that margin above the sum of rated power needs to be.

What that costs. A bigger generator means a bigger
purchase price: a 5.5 kW Marsun MVD6 costs 1 969 €, while a 20 kW Marsun MHD20B already costs 6 299 €. On top of that, a generator sized with a large margin for
startups runs lightly loaded during ordinary work — which means higher fuel
consumption per kilowatt-hour produced and faster engine wear if it
systematically runs far from its optimal load.

When the right answer is battery storage with a hybrid inverter

A battery wins where the grid essentially works fine, but short
simultaneous startups several times a day briefly exceed your agreed capacity
or simply spike above the property’s load profile. That’s the most common
situation at an auto-repair, joinery, or metalworking workshop: a compressor,
welder, and grinder rarely run all day at full power at once, but their
startups can coincide for an instant.

A second case is when a workshop plans to add a new, more powerful
machine and finds out it will need a higher agreed capacity. A battery
sometimes removes that need entirely, because the peak itself lasts seconds,
not hours.

The mechanism — ESO states what happens once you exceed agreed capacity:

„Atkreipiame dėmesį, kad viršijus objekto leistiną naudoti galią, vartotojas
privalo sumokėti trigubą vartotojo objektui taikomo tarifo plano galios
dedamosios kainą.“ (in English: Please note that if a property exceeds its
agreed capacity, the customer must pay triple the capacity charge under
their tariff plan.)

ESO — Elektros energijos persiuntimo paslaugų kainos verslui

With a base capacity charge of €3.00/kW/month, the triple rate means
€9.00/kW/month. If a short startup spike of a few kilowatts crosses the
limit several times a month, the yearly total adds up to more than a single
bill would suggest.

What that costs. During a long grid outage, a battery
doesn’t run indefinitely — its capacity is finite, and it’s not suited to a
long-lasting fault. On top of that, the battery and inverter combination must
match the manufacturer’s requirements: a 5 kW inverter with one battery
(€1,799) suits a small workshop with one or two powerful machines, while a
workshop with several machines will already need a bigger kit.

When the right answer is raising agreed capacity

This path wins once the peaks at your property stop being short and rare
and become a regular part of the work routine — for example, a workshop buys
a powerful new machine and now regularly exceeds its old limit several times
per shift. In that case, paying triple for every overrun ends up more
expensive over time than simply raising the agreed capacity.

The mechanism is the opposite of a battery’s: here you’re not reducing the
peak but legalising a higher ceiling. What that costs. Every
extra kilowatt of agreed capacity means €3.00/kW per month excluding VAT,
paid continuously, even if the new peak occurs rarely. Unlike a generator or
a battery, this is a solution with no one-off investment, but with a monthly
charge that never stops.

What the machines themselves decide for you

Some choices disappear before you’ve even had a chance to form an
opinion.

Three-phase power is a requirement, not a choice. Larger
compressors, lathes, and milling machines only run on a three-phase supply.
Every diesel model in our generator range is three-phase — there’s no
point looking for a single-phase option for machines like these.

Without an AVR it’s the electronics that suffer, not the
generator’s power.
Without a voltage regulator (AVR), the machine and
its electronics take voltage spikes — a risk unrelated to starting current,
relevant even when the generator has more than enough power. All our diesel generators come with an AVR.

Above 20 kW the ATS is built in. In our catalogue, separate ATS units exist for 6–15 kW (€199) and 20 kW (€269) generators. Marsun MHD generators from 25 kW up already have an ATS built in, so no separate unit or extra sizing step is needed.

Your reliability category adds another line to the bill.
For second- and third-group properties, ESO applies a reliability-category
charge — €1.00/kW/month for the first category, €0.50/kW/month for the
second. It needs to be calculated together with the capacity charge, not
separately.

What changes in day-to-day operation

A generator demands a routine: test runs, fuel reserves, oil changes. A
unit no one’s touched in a while can simply fail to start at the exact moment
it was bought for.

A battery and hybrid inverter don’t need daily maintenance, but they do
need an upfront decision: which panel circuits (compressor, lighting,
machine tools) stay connected to the battery, and which don’t. That’s decided
at installation.

What doesn’t change: none of the three options changes
your electricity supplier or meter. The property stays the same ESO customer
with the same (or officially increased) agreed capacity.

Do you really have to pick just one?

Most of the time a workshop is better off combining two solutions for two
different problems rather than picking one.

A generator with AVR for outages, without a big startup
margin.
Suits a workshop where machines rarely start at the same
time — the generator is bought for the average load with a small safety
margin, not a large “just in case” one.

A battery for the daily peak, a generator for the rare long
outage.
Suits a workshop with several powerful machines and frequent
short startups: the battery shaves the daily peak and protects against the
triple rate, while the generator remains insurance against a long fault.

Raising agreed capacity with no extra equipment at all.
Suits a case where the new peak has become a permanent part of the workflow
rather than a rare coincidence — here, extra equipment would only postpone an
inevitable decision.

Frequently asked questions

Why can a generator sized for the sum of my machines’ power still fail when I start them together?

Because a machine’s rated power reflects steady running, not the moment of
startup. A motor or transformer draws more than its rated power the instant
it starts, and when several devices’ startups coincide, the generator’s
margin may run out even though it would easily handle the same power running
steadily.

How do I find out what generator capacity my workshop needs?

The required capacity is determined not by your machines’ total power but
by the heaviest simultaneous startup — that is, which devices can realistically
switch on at the same time. Send us your list of machines and note which of
them can run together, and we’ll calculate it for your specific case.

Can a battery completely replace a generator in a workshop?

Not in every situation. A battery handles short, second- or minute-long
peaks well while the grid is up. For a long grid outage, its capacity may not
be enough — that depends on the battery’s size and how much equipment stays
connected during the outage.

What happens if a startup spike briefly exceeds my agreed capacity?

ESO states that exceeding a property’s agreed capacity means paying
triple the tariff plan’s capacity charge. With a base rate of
€3.00/kW/month, that’s €9.00/kW/month — and this rule applies even to a
brief, second-long overrun.

Why does an AVR matter if the generator already has enough power?

An AVR stabilises output voltage as the load changes — without it, the
machine and sensitive electronics take voltage spikes that, over time, damage
control boards and motor-control units. That’s a risk unrelated to whether the
generator has enough power for the startup itself.

What we suggest you do

Send us three things: your workshop’s agreed capacity (stated in your ESO
contract), a list of your machines and equipment with their power ratings,
and a note on which of them can realistically start at the same time. That’s
enough for us to tell you whether you need a bigger generator, a battery, or
a capacity increase — or a combination of these. We deliver across
Lithuania.

Sources

  • ESO, Electricity distribution service prices for business customers — capacity charge, reliability categories, capacity overrun:
    eso.lt (reviewed 2026-09-18)
  • Hybrid Energy, Marsun MVD6 technical specification — nominal and maximum power:
    hybridenergy.lt (reviewed 2026-09-18)
  • Hybrid Energy, generator and battery storage catalogue — models, kits, prices:
    hybridenergy.lt (reviewed 2026-09-18)